Image
image
image
image


Unvented Twin Coil Cylinders Technical Specifications
These cylinders are used for systems where the back-up to the solar heating is via a gas or oil fired conventional boiler or solid fuel boiler such as an Aga, wood-burning stove, Rayburn etc. 

Solar unvented cylinder

Tank material: Duplex Stainless steel
Coil in coil heat exchangers giving high recovery rate
Min working pressure: 1 bar
Max working pressure: 15 bar
Min water supply at 1.5 bar 20 litres per minute.
Insulation thickness: 60mm
Control settings:
1. Pressure reducing valve 3 bar
2. Expansion relief valve 6 bar
3. Temperature and pressure relief valve 7bar & 90 C
4. High limit stat 85 C.
22mm connections
2 year guarantee, 25 year vessel guarantee
 

Capacity
(litres)

Dimensions
(Diameter x Height)

Empty weight
(kg)
150 545 x 1102 40
180 545 x 1290 45
210 545 x 1478 48
250 545 x 1728 53
300 545 x 2041 63
Unvented Single Coil Cylinders Technical Specifications
These cylinders are used for systems where the back-up to the solar heating is only via the electric immersion heater.  

Single coil cylinder unvented

Tank material: Duplex Stainless steel
Coil in coil heat exchangers giving high recovery rate
Min working pressure: 1 bar
Max working pressure: 15 bar
Min water supply at 1.5 bar 20 litres per minute.
Insulation thickness: 60mm
Control settings:
1. Pressure reducing valve 3 bar
2. Expansion relief valve 6 bar
3. Temperature and pressure relief valve 7bar & 90 C
4. High limit stat 85 C.
22mm connections
2 year guarantee, 25 year vessel guarantee
 

Capacity
(litres)

Dimensions
(Diameter x Height)

150 545 x 1102
180 545 x 1290
210 545 x 1478
250 545 x 1728
300 545 x 2041

 

image
image